Xbd Vertical Multistage Stage Fire-Fighting Centrifugal Pump

Model NO.: XBC/XBD
Power: Electric, Diesel Engine
Start Up: Electric Pump, Engine Pump, Control Panel
Type: Fire Pump
Application: Clarified Water Pump, Fire Fighting Pump
Industry: Fire Fighting Pump
Media: Clean Water, Sea Water
Performance: Fire Fighting/ Irrigation/Mining
Theory: Centrifugal Pump
Capacity Range: 10L/S-200L/S
Pressure Range: 0.3MPa-2.5MPa
Power Range: 7.5kw-360kw
Speed: 740 - 3600 R/Min
Effi. %: 63%-83%
Accessories: Control Panel, Pipe, Valve, Calbe
Component: Diesel Engine Pump, Electric@Jockey Pump, Starter
Head: 30-240 M
Trademark: Blank
Transport Package: Standard Export Plywood Case for Each Water Pump
Specification: CE, SGS, ISO9001
Origin: Fujian, China
HS Code: 8413709990
Model NO.: XBC/XBD
Power: Electric, Diesel Engine
Start Up: Electric Pump, Engine Pump, Control Panel
Type: Fire Pump
Application: Clarified Water Pump, Fire Fighting Pump
Industry: Fire Fighting Pump
Media: Clean Water, Sea Water
Performance: Fire Fighting/ Irrigation/Mining
Theory: Centrifugal Pump
Capacity Range: 10L/S-200L/S
Pressure Range: 0.3MPa-2.5MPa
Power Range: 7.5kw-360kw
Speed: 740 - 3600 R/Min
Effi. %: 63%-83%
Accessories: Control Panel, Pipe, Valve, Calbe
Component: Diesel Engine Pump, Electric@Jockey Pump, Starter
Head: 30-240 M
Trademark: Blank
Transport Package: Standard Export Plywood Case for Each Water Pump
Specification: CE, SGS, ISO9001
Origin: Fujian, China
HS Code: 8413709990
XBD Vertical Multistage Stage Fire-Fighting Centrifugal Pump
Introduction
XBC series Diesel engine fire-fighting pump  is a new-style fire fighting equipment, which is developed upon the fitted fire fighting pumps (single stage single suction type, singlestage dualsuction type and sectional multistage type), can be divided into several series. The equipment has a wide range of pressure and temperature and can be used for almost every occasion necessary for fire fighting purpose.The diesel engine fitted with the equipment is an excellent product domestic or imported, features good starting performance, strong overload capacity, compact structure, easy maintenance and use and high degree of automation.
XBD Series Electricity Fuel Centrifugal Fire Fighting Water Pump is the new middle and low pressure fire fighting product, which researched by our company according to the latest standard(GB 6425-1998) of fire fighting pump in our country, its motor and fire pump is connected directly, which simplified the middle transmitting structure, and strengthen operation's stability. Its building area is less 30% than common horizontal fire pump, the shaft seal adopts hard alloy mechanical seal without leakage, its inlet and outlet can be installed at any position and any direction like valve, its noise is low, maintenance is convenient, shake is little and so on. XBD series include four structural types to meet the different requirements of users, including vertical single-stage fire pump, vertical multistage fire pump, horizontal single-stage fire pump and horizontal multistage fire pump.

Specification
Name Electric or diesel engine driven centrifugal fire fighting water pump
Pumped medium Water or other liquid
Fire pump flow 1.5~1550m3/h
Fire pump head 16~380m
Inlet & Outlet diameter DN25~600mm
Fire Pump material Cast iron/Stainless steel
Speed 980~3500rpm
Diesel / motor power 0.75~580kW
Diesel Cylinder numbers 1/2/4/6/8
Straing method 12/24V battery starter for diesel engine
Motor Electric 110~525V
Medium temperature -15~+120ºC
 
Components:
1.Electric pump: kinds of end suction pump, split case pump, multistage pump.
made of cast iron, stainless steel.  Impeller can be bronze. 
5.5-710 kw    0.3-1.2 mpa    10-420 l/s (150-6600GPM
2.Diesel pump:   Flow is the same with electric pump. 
It connects the pump set with  High elastic coupling or universal joint.
It also includes water tank, oil tank, fans, control screen etc.     
7.0-810 kw    0.3-1.2 mpa     10-420 l/s (150-6600GPM)
3.Jockey pump:  horizontal or vertical, small flow,  
head is higher than electric or diesel pump 
4.Control panel:  control the pumps automatically with overload, overcurrent protection 
5.Accessories:    check valve, gate valve, pressure tank (0.6mpa, 1.0mpa, 1.6mpa)   
Pressure gauge, pressure sensors, import and export common pipe,   
soft joints, flanges and common base.
 
XBC Model Form
Model Speed
(r/min)
Capacity
(L/S)
Pressure
(Mpa)
Effi
(%)
NPSH
(m)
Shaft Power
(KW)
Diesel Power
(KW)
Inlet/Outlet
(mm)
Weight
(Kg)
3/10 2000 10 0.3 71 2.5 5.5 7.5 100/65 91
3/20 2000 20 0.3 71 3 9.5 13.8 100/65 91
3/30 2000 30 0.3 69 3.8 16.8 20.6 125/100 129
3/40 2000 40 0.3 77 4.8 18.5 23.2 125/100 129
4/10 2000 10 0.4 71 2.5 7.4 13.8 100/65 91
4/20 2000 20 0.4 77 3 11.2 15.3 125/100 129
4/30 2000 30 0.4 74 3.6 18.2 26.5 125/100 145
5/10 2000 10 0.5 65 4.2 8.7 13.8 100/65 120
5/20 2000 20 0.5 65 4.5 19.9 26.5 100/65 120
5/30 2000 30 0.5 74 4.5 25.7 35.3 125/100 145
5/40 2000 40 0.5 74 4.9 32.8 35.5 125/100 145
5/50 1500 50 0.5 75 2.8 36.3 58 150/125 212
5/100 1500 100 0.5 81 3.8 67.2 105 200/150 245
5/110 1500 110 0.5 81 4.5 68.4 105 200/150 245
6/10 2000 10 0.6 65 2.5 11.5 15.3 100/65 120
6/20 2000 20 0.6 74 3 19.7 26.5 125/100 145
6/30 2000 30 0.6 74 3.6 29.7 40.4 125/100 145
4/30 1500 30 0.4 75.5 4.1 15.6 20.6 125 475
6/30 1500 30 0.6 75.5 4.1 23.4 31.6 125 555
8/30 1500 30 0.8 75.5 4.1 31.2 34.3 125 640
10/30 1500 30 1 75.5 4.1 39 58 125 726
12/30 1500 30 1.2 75.5 4.1 46.8 75 125 840
14/30 1500 30 1.4 75.5 4.1 54.6 75 125 923
16/30 1500 30 1.6 75.5 4.1 62.4 75 125 1008
18/30 1500 30 1.8 75.5 4.1 70.2 110 125 1093
6/40 1500 40 0.6 77 3.9 32.8 58 150 490
9/40 1500 40 0.9 77 3.9 49.3 75 150 575
12/40 1500 40 1.2 77 3.9 65.7 75 150 660
15/14 1500 40 1.5 77 3.9 82.1 110 150 745
18/40 1500 40 1.8 77 3.9 98.5 160 150 830
8/80 1500 80 0.8 77 4.7 85.2 110 200 667
12/80 1500 80 1.2 77 4.7 127.7 160 200 787
16/80 1500 80 1.6 77 4.7 170.3 220 200 907
20/80 1500 80 2 77 4.7 212.3 279 200 1027
25/80 1500 80 2.5 77 4.7 255.5 Drive Axle

As the main component of the loader, the drive axle further increases the torque transmitted from the output shaft of the transmission and the speed is further reduced to overcome the resistance of the wheels, and at the same time transfer the input power to the wheels by changing the direction of 90°.
What is the difference between dry axle and wet axle of loader?
1. Different brakes:
Dry and wet brakes are for the brakes on the axle. Dry axles use caliper disc brakes with the brakes and brake discs exposed to the outside; wet axle brake pads are enclosed in the axle housing and immersed in gear oil. Rely on oil circulation to dissipate heat.

2. Different wear resistance
Compared with the two, dry brakes are susceptible to material contamination and abrasion, and wet brakes can be maintenance-free because they are fully enclosed.
Most domestic loaders use dry axles. Export models and foreign brand machines all use wet axles. Wet bridges are also the direction of technological development.

SEM 50F, 650 drive axle
Liugong loaders ZL50CN, 855N, 856 drive axle,
SDLG 956L 952H 953 drive axle,
XCMG drive axle LW500KL ZL50GN,
Komatsu WA380, WA380-3, WA380-5, WA430-5 drive axle
DEGONG loader drive axle
Foton Lovol Loader drive axle
Lonking 855N loader drive axle
XGMA 932 936 956 Loader drive axle
Changlin Loader drive axle
Shantui SL50W drive axle
And we have more.



Drive Axle,High Precision Drive Axle,Drive Axle Of Excavator,Drive Motor Bearing

Drive Axle,High Precision Drive Axle,Drive Axle Of Excavator,Drive Motor Bearing

Jinan Union Construction Machinery Co., Ltd. , https://www.tfloaderparts.com