Oil Pressure Gauge Water Meter Accessories
YY(Q)W series thermal oil fluid boiler adopts horizontal chamber combustion three-coil structure, and its body is composed of outer coil, middle coil,inner coil and rear coil. USES: oil chemical industry/chemical fiber industry/wood processing/paper making/building materials/food industry, etc. Gas Thermal Oil Boiler,Automatic Gas Fired Thermal Oil Boiler,Industrial Gas Fired Thermal Oil Boiler,Gas Fuel Thermal Oil Boiler,Thermal Oil Boiler Gas Fired Henan Yuanda Boiler Co., Ltd. , https://www.industrysteamboiler.com
Descripation:
Nominal size: 40, 50, 63, 80, 100, 160
Accuracy: 2.5, 1.6
Permissible temperature:
When temperature departure is ± 5° C, additional temperature error is not more than 0.4%° C/10° C.
Standard version:
Process connection: Cu-alloy, Radial and axial
Φ 40: G 1/8 B (male), 14 mm flats
Φ 50 or Φ 63: G 1/4 B (male), 14 mm flats
Φ 80, Φ 100 or Φ 160: G 1/2 B (male), 22 mm flats
Pressure element: Cu-alloy,
≤ 60 bar: C-type
> 60 bar: Helical type
Movement: Cu-alloy
Dial: Aluminium, white, with pointer stop pin
Black or red lettering(can be with customer's logo)
Case: Plastic or Steel, black Φ 160 Steel, black
Design for window: Snap on plastic(for plastic case ),
Screw in polycarbonatesteel,
Steel black bezel(two screws )with glass window
Note:
1. There are radial and axial for selecting
2. Thread: NPT, BSP, BSPT etc
3. Rubber for gauges in Φ 40, Φ 50, Φ 63 and Φ 80
4. U-clamp for gauges in Φ 40, Φ 50, Φ 63 and Φ 100
5. Flange Φ 40, Φ 50, Φ 63, Φ 100 and Φ 160
Name
Model
Remark
Shock-proof oil pressure gauge
0.7/1.0/1.6/2.5/3.0Mpa
CK63 Radial Direction/Pipeline
Shock-proof oil pressure gaugeф63
0.7/1.0/1.6/2.5/3.0Mpa
CK63 Axial Direction with Edge/Panel
Shock-proof oil pressure gaugeф63
0.7/1.0/1.6/2.5/3.0Mpa
CK63 Shaft Forward Edge
Shock-proof oil pressure gaugeф100
0.7/1.0/1.6/2.5/3.0Mpa
CK100 Radial Direction/Axial Direction
Shock-proof oil pressure gaugeф100
0.7/1.0/1.6/2.5/3.0Mpa
CK100 Forward Edge
Electro connecting pressure gauge
0.7/1.0/1.6/2.5Mpa
Radial Direction/Pipeline
Ordinary water pressure gauge
0.7/1.0/1.6Mpa
Radial Direction/Pipeline
Company Introduction
Guangzhou Chunke Environmental Technology Co., Ltd. In the water treatment industry, with Its extensive field experience and technical development capabilities, combined with the Global industrial water treatment and new materials, new technologies developed on the basis Of a series of technologically advanced, affordable, reliable water treatment systems, industrial Water treatment systems company dedicated to product development, design and manufacturing,Equipment supply, Project installation, technical support, service, etc., and create a leading,Highquality, highly efficient and robust water treatment program, widely used in electricity,Electronics, electroplating, chemical,pharmaceutical, food and beverage, building materials,Domestic water and other fields.
If you have another question, please feel free to contact me as follow
Mobile: 86-18122353314
Fax: 86-020-22895083
Contact person :Â Sue Jiang
Website: www.gzchunke.comÂ
Address: No.8, Suyuangzhuang, QingHu Village, Junhe Street,
Baiyun District, Guangzhou. China
Oil Pressure Gauge Water Meter Accessories
Descripation:
Nominal size: 40, 50, 63, 80, 100, 160
Accuracy: 2.5, 1.6
Permissible temperature:
When temperature departure is ± 5° C, additional temperature error is not more than 0.4%° C/10° C.
Standard version:
Process connection: Cu-alloy, Radial and axial
Φ 40: G 1/8 B (male), 14 mm flats
Φ 50 or Φ 63: G 1/4 B (male), 14 mm flats
Φ 80, Φ 100 or Φ 160: G 1/2 B (male), 22 mm flats
Pressure element: Cu-alloy,
≤ 60 bar: C-type
> 60 bar: Helical type
Movement: Cu-alloy
Dial: Aluminium, white, with pointer stop pin
Black or red lettering(can be with customer's logo)
Case: Plastic or Steel, black Φ 160 Steel, black
Design for window: Snap on plastic(for plastic case ),
Screw in polycarbonatesteel,
Steel black bezel(two screws )with glass window
Note:
1. There are radial and axial for selecting
2. Thread: NPT, BSP, BSPT etc
3. Rubber for gauges in Φ 40, Φ 50, Φ 63 and Φ 80
4. U-clamp for gauges in Φ 40, Φ 50, Φ 63 and Φ 100
5. Flange Φ 40, Φ 50, Φ 63, Φ 100 and Φ 160
Name
Model
Remark
Shock-proof oil pressure gauge
0.7/1.0/1.6/2.5/3.0Mpa
CK63 Radial Direction/Pipeline
Shock-proof oil pressure gaugeф63
0.7/1.0/1.6/2.5/3.0Mpa
CK63 Axial Direction with Edge/Panel
Shock-proof oil pressure gaugeф63
0.7/1.0/1.6/2.5/3.0Mpa
CK63 Shaft Forward Edge
Shock-proof oil pressure gaugeф100
0.7/1.0/1.6/2.5/3.0Mpa
CK100 Radial Direction/Axial Direction
Shock-proof oil pressure gaugeф100
0.7/1.0/1.6/2.5/3.0Mpa
CK100 Forward Edge
Electro connecting pressure gauge
0.7/1.0/1.6/2.5Mpa
Radial Direction/Pipeline
Ordinary water pressure gauge
0.7/1.0/1.6Mpa
Radial Direction/Pipeline
Company Introduction
Guangzhou Chunke Environmental Technology Co., Ltd. In the water treatment industry, with Its extensive field experience and technical development capabilities, combined with the Global industrial water treatment and new materials, new technologies developed on the basis Of a series of technologically advanced, affordable, reliable water treatment systems, industrial Water treatment systems company dedicated to product development, design and manufacturing,Equipment supply, Project installation, technical support, service, etc., and create a leading,Highquality, highly efficient and robust water treatment program, widely used in electricity,Electronics, electroplating, chemical,pharmaceutical, food and beverage, building materials,Domestic water and other fields.
If you have another question, please feel free to contact me as follow
Mobile: 86-18122353314
Fax: 86-020-22895083
Contact person :Â Sue Jiang
Website: www.gzchunke.comÂ
Address: No.8, Suyuangzhuang, QingHu Village, Junhe Street,
Baiyun District, Guangzhou. China
Core Technology:
1. Oil cover fire structure with three pass
2. Wet back structure
3. Compact coil tube
4. Over oil temperature/over smoke temperature/low flow alarm
5. Liquid level protection and flameout protection
6. Front and rear big open door design
7. Design with air preheater or heat recovery boiler