Water Chiller Air Treatment Unit
May be the cabinet of aluminium alloy used for manufacturing later, people developed the push-pull cabinet.Push-pull cabinet did not stop the problem, because of push-pull cabinet casement opening and closing of stationary state basic same. Cabinet Hardware,Zinc Die Casting Cabinet Handle,Zinc Die Casting Cabinet Switch,Coated Cabinet Hardware NINGBO ZHENHAI BOLANG METAL PRODUCT FACTORY , http://www.blcastings.com
a)Low Noise
b)Efficient and Energy Saving
c)Easy Operation and Installation
d)Compact Exterior
e)High quality
f)Competitive price
Â
2.Product series-Eurostars chilled water fan coil-air handling unit
-Horizontal ceiling ducted air handling unit
-Horizontal concealed air handling unit
-Vertical concealed air handling unit
-Vertical exposed air handling unit
-Modulus Air Handling Unit-multi-function air handling unit
Â
3.Unit specification-air handling unit
Following is only one part of our whole air handling unit specification,please ask Eurostars salesman for other detailed specification.
Heat exchanger:4Rows
Model
Air Flow Volume
Motor-external Linked
 Return Air
Rated Air Flow
Air Flow Range
Pressure
Power Input
Cooling Capacity
Heating Capacity
Water Flow
Water Resistance
Water inlet/outlet pipe Diameter
*1000CMH
Pa
kW
kW
L/min
kPa
DN
EST2HC4
2
1.7~2.2
150
0.55
11.44
18.41
34.5
3
32
EST3HC4
3
2.2~3.4
200
0.75
13.89
22.36
41.9
3.5
32
EST4HC4
4
3.4~4.4
250
1.1
20.63
33.21
62.2
4.7
40
EST5HC4
5
4.4~5.4
250
1.5
25.74
41.44
77.6
6.2
40
EST6HC4
6
5.4~6.7
300
2.2
30.91
49.76
93.2
8.5
40
EST8HC4
8
6.7~8.7
300
2.2
41.26
66.42
124.4
10.5
50
EST10HC4
10
8.7~10.8
350
3
51.61
83.09
155.6
14.5
50
EST12HC4
12
10.8~13
350
4
62.12
100.01
187.3
15.1
50
EST15HC4
15
13~15.4
400
5.5
73.87
118.93
222.7
15.8
65
EST16HC4
16
15.4~16.8
400
5.5
79.61
128.17
240
16.2
65
EST18HC4
18
16.8~18.8
400
7.5
91.05
146.59
274.5
16.4
65
EST20HC4
20
18.8~21.5
500
2*4
103.6
166.79
309
16.6
65
EST24HC4
24
21.5~25.5
500
2*5.5
130
209.3
387.8
16.8
2*65
EST27HC4
27
25.5~28.5
500
2*5.5
149.8
241.17
446.8
17.5
2*65
EST30HC4
30
28.5~31
500
2*7.5
169.6
273.05
505.9
18.3
2*65
EST32HC4
32
31~32.8
500
2*7.5
183.9
296.07
548.5
18.7
2*65
EST34HC4
34
32.8~34.8
550
2*7.5
195.8
315.23
584
19.1
2*65
EST36HC4
36
34.8~37.5
550
2*7.5
206.9
333.1
617.3
19.4
2*65
EST40HC4
40
37.5~42
600
2*11
230.8
371.58
681.5
20.2
2*65
EST45HC4
45
42~47
600
2*11
259
416.99
764.5
22.2
2*65
EST50HC4
50
47~52
650
2*11
287.2
462.39
848.1
25
2*65
EST55HC4
55
52~57
650
2*11
316.2
509.08
933.7
28.3
2*65
EST60HC4
60
57~64.5
700
2*15
345.4
556.09
1020
31.7
2*65
EST70HC4
70
64.5~75
700
2*15
402.4
647.86
1188
38.4
2*80
Heat exchangers:6Rows
Model
Air Flow Volume
Motor-external Linked
 Return Air
Rated Air Flow
Air Flow Range
Pressure
Power Input
Cooling Capacity
Heating Capacity
Water Flow
Water Resistance
Water inlet/outlet pipe Diameter
*1000CMH
Pa
kW
kW
L/min
kPa
DN
EST2HC6
2
1.7~2.2
150
0.55
15.4
24.79
46.5
3.8
32
EST3HC6
3
2.2~3.4
200
0.75
18.7
30.1
56.5
4.4
32
EST4HC6
4
3.4~4.4
250
1.1
27.8
44.75
83.9
6
40
EST5HC6
5
4.4~5.4
250
1.5
34.7
55.86
104.7
7.9
40
EST6HC6
6
5.4~6.7
300
2.2
41.7
67.13
125.8
10.8
40
EST8HC6
8
6.7~8.7
300
2.2
55.7
89.67
167.9
13.4
50
EST10HC6
10
8.7~10.8
350
3
69.7
112.21
210
18.5
50
EST12HC6
12
10.8~13
400
4
83.9
135.07
252.8
19.2
65
EST15HC6
15
13~15.4
400
5.5
99.7
160.51
300.6
20.1
65
EST16HC6
16
15.4~16.8
400
5.5
107.5
173.07
324
20.7
65
EST18HC6
18
16.8~18.8
400
7.5
122.9
197.86
370.5
20.9
65
EST20HC6
20
18.8~21.5
500
2*4
139.8
225.07
417.1
21.2
65
EST24HC6
24
21.5~25.5
500
2*5.5
175.5
282.55
523.5
21.4
2*65
EST27HC6
27
25.5~28.5
500
2*5.5
202.2
325.54
603.1
22.3
2*65
EST30HC6
30
28.5~31
500
2*7.5
228.9
368.52
682.9
23.3
2*65
EST32HC6
32
31~32.8
500
2*7.5
248.2
399.6
740.4
23.9
2*65
EST34HC6
34
32.8~34.8
550
2*7.5
264.3
425.52
788.4
24.4
2*65
EST36HC6
36
34.8~37.5
550
2*7.5
279.3
449.67
833.3
24.7
2*65
EST40HC6
40
37.5~42
600
2*11
311.6
501.67
920
25.8
2*65
EST45HC6
45
42~47
600
2*11
349.6
562.85
1032.2
28.3
2*65
EST50HC6
50
47~52
650
2*11
387.8
624.35
1144.9
31.9
2*65
EST55HC6
55
52~57
650
2*11
426.9
687.3
1260.4
36.1
2*80
EST60HC6
60
57~64.5
700
2*15
466.3
750.74
1376.7
40.5
2*80
EST70HC6
70
64.5~75
700
2*15
534.2
874.5
1603.8
49
2*80
Heat exchangers:8Rows
Model
Air Flow Volume
Motor-external Linked
 Return Air
Rated Air Flow
Air Flow Range
Pressure
Power Input
Cooling Capacity
Heating Capacity
Water Flow
Water Resistance
Water inlet/outlet pipe Diameter
*1000CMH
Pa
kW
kW
L/min
kPa
DN
EST2HC8
2
1.7~2.2
150
0.55
19.43
31.28
58.6
4.6
32
EST3HC8
3
2.2~3.4
200
0.75
23.61
38.01
71.2
5.4
32
EST4HC8
4
3.4~4.4
250
1.1
35.06
56.44
105.7
7.3
40
EST5HC8
5
4.4~5.4
250
1.5
43.75
70.43
131.9
9.7
40
EST6HC8
6
5.4~6.7
300
2.2
52.54
84.58
158.4
13.2
50
EST8HC8
8
6.7~8.7
300
2.2
70.12
112.89
211.4
16.4
50
EST10HC8
10
8.7~10.8
350
3
87.73
141.24
264.5
22.6
50
EST12HC8
12
10.8~13
350
4
105.61
170.03
318.4
23.6
65
EST15HC8
15
13~15.4
400
5.5
125.55
202.13
378.5
24.7
65
EST16HC8
16
15.4~16.8
400
5.5
135.33
217.88
408
25.3
65
EST18HC8
18
16.8~18.8
400
7.5
154.77
249.17
466.6
25.6
65
EST20HC8
20
18.8~21.5
500
2*4
174.24
280.52
525.3
25.9
65
EST24HC8
24
21.5~25.5
500
2*5.5
218.66
352.04
659.2
26.2
2*65
EST27HC8
27
25.5~28.5
500
2*5.5
251.93
405.6
759.5
27.3
2*65
EST30HC8
30
28.5~31
500
2*7.5
285.26
459.26
860
28.6
2*65
EST32HC8
32
31~32.8
500
2*7.5
309.28
497.94
932.4
29.2
2*65
EST34HC8
34
32.8~34.8
550
2*7.5
329.32
530.2
992.8
29.8
2*65
EST36HC8
36
34.8~37.5
550
2*7.5
348.09
560.42
1049.4
30.3
2*65
EST40HC8
40
37.5~42
600
2*11
384.28
618.69
1158.5
31.6
2*65
EST45HC8
45
42~47
600
2*11
431.15
694.15
1299.8
34.7
2*65
EST50HC8
50
47~52
650
2*11
478.22
769.93
1441.7
39.1
2*65
EST55HC8
55
52~57
650
2*11
523.5
842.83
1578.2
44.2
2.*80
EST60HC8
60
57~64.5
700
2*15
575.04
925.81
1733.6
49.5
2*80
EST70HC8
70
64.5~75
700
2*15
669.91
1078.55
2019.6
60
2*100
4.Eurostars Quotation Remarks-Air handling unit
1.Packing: Standard export package
2.Delivery Day: 20 working days after deposit is confirmed
3.Delivery term: CIF,FOB or CNF EX-Work are welcomed
4.Payment term: 30% deposit by TT, the balance will be paid by TT before delivery;
  Or 100% Irrevocable non-transferred LC at sight
5.Warranty: 12~18 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
6.Validity:Â 20Â days
7.Payment currency: USD
Â
5.CERTIFICATE--Â CEÂ certificated
1.Selling Point-Eurostars chilled water fan coil-air handling unit
a)Low Noise
b)Efficient and Energy Saving
c)Easy Operation and Installation
d)Compact Exterior
e)High quality
f)Competitive price
Â
2.Product series-Eurostars chilled water fan coil-air handling unit
-Horizontal ceiling ducted air handling unit
-Horizontal concealed air handling unit
-Vertical concealed air handling unit
-Vertical exposed air handling unit
-Modulus Air Handling Unit-multi-function air handling unit
Â
3.Unit specification-air handling unit
Following is only one part of our whole air handling unit specification,please ask Eurostars salesman for other detailed specification.
Heat exchanger:4Rows
Model
Air Flow Volume
Motor-external Linked
 Return Air
Rated Air Flow
Air Flow Rang
One disadvantage of push-pull cabinet is a must have at least one fixed fan, greatly reduce the cabinet area: the other is a fatal weakness could not meet the requirements of air tightness and water tightness.
Of push-pull cabinet casement fixed point is up and down two guide rail, so the wind pressure strength is limited.Modern building more and more high to the requirement of energy conservation and other functions, the sealing of the cabinet, sound insulation and heat insulation, air tightness and water tightness and wind resistance strength and security level, there are strict requirements.To meet the requirements of a variety of integrated and produced within the batter casement cabinets, or the Europe type cabinet.
The cabinet of modern glass curtain wall building model related to the cabinet frame on the wall of the fixed way.Because the glass curtain wall of air tightness, water tightness and wind resistance strength of the demand is higher, on the curtain wall cabinet accessories, according to the need to develop relatively independent.
Modern architecture of the cabinet is not confined to the level of manpower and starting from the requirements of ventilation heat removal, the height of the cabinet is an important factor decided to take a breath row of thermal efficiency, so people invented all kinds of cabinet.