Roots pumps the correct installation method
Dust Mite Vacuum,Dust Free Vacuum Cleaners,Dust Mite Vacuum Cleaner,Wireless Dust Mite Vacuum GUANGDONG DEERMA TECHNOLOGY CO., LTD. , https://www.fsdeerma.com
2. The pipe should be pipe rack, the pump is not allowed to withstand the load pipe 3. In the pump inlet and outlet should be installed vacuum gauge and pressure gauge, in order to observe the pump work 4. In the Roots pump inlet pipe should be installed Filter device to prevent large particles of impurities into the pump chamber, damaging the pump 5. In order to pump and motor safety work, overload protection device should be installed in the electrical system 6. Pipe elbow should be minimized, and the elbow radius as large as possible , To avoid vibration