X Ray Baggage Luggage Scanner Inspection Equipment
We're the original supplier and can provide you Safeway Inspection System Limited. Address: Room 308, E Building, QiFeng Digital Park, BaiNiKeng, PingHu Street, LongGang District, Shenzhen, China, 518108 Tel: 0755-89342235 Fax: 0755-89342650 Mobile: +86-136 7021 3490 Website: www.safeway-system.com To be the best manufacturer of cargo and vehicle inspection system We're the original supplier and can provide you Safeway Inspection System Limited. Address: Room 308, E Building, QiFeng Digital Park, BaiNiKeng, PingHu Street, LongGang District, Shenzhen, China, 518108 Tel: 0755-89342235 Fax: 0755-89342650 Mobile: +86-136 7021 3490 Website: www.safeway-system.com To be the best manufacturer of cargo and vehicle inspection system SEM wheel loader 50F, 650 Air Conditioner, Lonking 855 air conditioner, Liugong loader ZL50CN, 855N, 856 air conditioner, SDLG wheel loader 956L 952H 953 air conditioner, XCMG wheel loader air conditioner LW500KL ZL50GN, Komatsu WA380, WA380-3, WA380-5, WA430-5 air conditioner Air Conditioner Air Conditioner,Air Conditioner Of Sdlg Loader,Air Conditioner Of Xcmg Loader,Warm Machine Of Xgma Loader Shandong Tianfu International Trade Co.,Ltd. , https://www.tfloaderparts.com
AT5030A X-ray Baggage scanner is a new type of security inspection equipment that uses X-ray to penetrate and check baggage and cargo without unpacking examination. It is applicable for security checks on briefcases, parcels, express mail, hand luggage, and small parcels in government agencies, transportation, logistics, courts, procuratorate, prisons, embassies, factories, schools, hospitals, gymnasiums, exhibition halls, and entertainment venues etc.
AT5030A belongs to the Linux product family, which is totally designed and manufacturer by our own company. Every year, we invest a large amount of labors and resources in the development of new technology and models. We own all the copyrights and patents, from the outlook design to the software. Safeway system is the market leader and one of the very few companies in China who can creat the new things instead of COPY.
Product highlights
* Linux operation system
* ARM CPU
* Digital signal and processor
* Continous hard work for 10000 hours
* Energy saving design
* High penetration
* Good quality images
Advantanges
Â
Â
Â
Equipment Functions
Â
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
Physical Specifications
Â
Unit weight (kgs)
250
Unit size (mm)
1660(L)*746(W)*1165(H)
after packed in wooden pallet -Â
Â
Gross weight (kgs)
320
Packing size
180*88*138cm
Â
General Specifications
Â
Tunnel size(mm)
503(L)*301(W)
Conveyor Speed(m/s)
0.22
Conveyor height(mm)Â
668.5
Conveyor Max Load(kgs)
100
X ray dose per each inspection
Typical 3.0 μGy, guarantee 3.5 μGy
X ray leakageÂ
Typical 2.0 μGy/h, guarantee 2.5 μGy/h
Penetration
Typical 6mm, guarantee 4mm
Wire Resolution
Typical AWG38, guarantee AWG36
Penetration Resolution
Typical AWG34, guarantee AWG32
Spatial resolution:
Typical dia1.3mm,Vertical: dia1.3mm; Guarantee dia1.6mm,Vertical: dia1.6mm;
Power Consumption
0.5KVA
Noise
< 60 dB
Film Safety
Guarantee ASA/ISO1600 FilmÂ
Â
Â
X-ray Generator (single)
Â
Anode Voltage
80 KV
Anode power
0.3mA
Generate angle
80 degree upwardÂ
Generate direct
from bottom to topÂ
Cooling / Duty Cycle
Oil Cooling /100%Â
Brand
made by ourself
Â
Â
Software System
Â
Self-test after power on
Self test after power-on, and show the problem
( 1. emergency stop, 2. housing panel is open 3. calibration fail
 4. detection system error 5. hard drive is missing)
Image Display
High resolution of 1024 * 1280 pixel;
Image Enhancement
Color/BW, negative, high/low
penetration, organic /inorganic Stripping, general enhancement, and pseudo color, etc.
Image Recall
30 images recallable, retrieval
Image Archive
Up to 500,000 images stored automatically, enable transferring to USB disk, and converting to JPG, BMP and other general formats
Real-time Curve
Real-time curve to see if the detection system and other components work well
Others
Fault diagnosis, system time setting, detection blind dots delete, x-ray source setting(analoge or digital), alarm setting, images setting, software register, user management, TIP report, data setting(machine working time, x-ray source working time, baggage counter, etc.)
Â
Â
Operating Environment
Â
Operation temperature/Humidity
5ºC-40ºC / 0%-90%(non-condensing)Â
Storage Temperature/Humidity
 -40ºCto 70ºC / 5%-95%(non-condensing)Â
Operation Power
 220VAC(±10%) 50±3Hz (Optional: 100VAC,110VAC,120VAC,200VAC)
Â
Â
Computer and other
Â
Monitor
High Resolution Color, LCD Accord, 17inch
Hard Disk
SEAGATE 500G 3.5"
CPU
Cortex A9
Storage
1GB
Main board
IMX6_mainboard-V030, made by Safeway
Safeway System -
Â
factory price, with best quality
Â
AT5030A X-ray Baggage scanner is a new type of security inspection equipment that uses X-ray to penetrate and check baggage and cargo without unpacking examination. It is applicable for security checks on briefcases, parcels, express mail, hand luggage, and small parcels in government agencies, transportation, logistics, courts, procuratorate, prisons, embassies, factories, schools, hospitals, gymnasiums, exhibition halls, and entertainment venues etc.
AT5030A belongs to the Linux product family, which is totally designed and manufacturer by our own company. Every year, we invest a large amount of labors and resources in the development of new technology and models. We own all the copyrights and patents, from the outlook design to the software. Safeway system is the market leader and one of the very few companies in China who can creat the new things instead of COPY.
Product highlights
* Linux operation system
* ARM CPU
* Digital signal and processor
* Continous hard work for 10000 hours
* Energy saving design
* High penetration
* Good quality images
Advantanges
Â
Â
Â
Equipment Functions
Â
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
Physical Specifications
Â
Unit weight (kgs)
250
Unit size (mm)
1660(L)*746(W)*1165(H)
after packed in wooden pallet -Â
Â
Gross weight (kgs)
320
Packing size
180*88*138cm
Â
General Specifications
Â
Tunnel size(mm)
503(L)*301(W)
Conveyor Speed(m/s)
0.22
Conveyor height(mm)Â
668.5
Conveyor Max Load(kgs)
100
X ray dose per each inspection
Typical 3.0 μGy, guarantee 3.5 μGy
X ray leakageÂ
Typical 2.0 μGy/h, guarantee 2.5 μGy/h
Penetration
Typical 6mm, guarantee 4mm
Wire Resolution
Typical AWG38, guarantee AWG36
Penetration Resolution
Typical AWG34, guarantee AWG32
Spatial resolution:
Typical dia1.3mm,Vertical: dia1.3mm; Guarantee dia1.6mm,Vertical: dia1.6mm;
Power Consumption
0.5KVA
Noise
< 60 dB
Film Safety
Guarantee ASA/ISO1600 FilmÂ
Â
Â
X-ray Generator (single)
Â
Anode Voltage
80 KV
Anode power
0.3mA
Generate angle
80 degree upwardÂ
Generate direct
from bottom to topÂ
Cooling / Duty Cycle
Oil Cooling /100%Â
Brand
made by ourself
Â
Â
Software System
Â
Self-test after power on
Self test after power-on, and show the problem
( 1. emergency stop, 2. housing panel is open 3. calibration fail
 4. detection system error 5. hard drive is missing)
Image Display
High resolution of 1024 * 1280 pixel;
Image Enhancement
Color/BW, negative, high/low
penetration, organic /inorganic Stripping, general enhancement, and pseudo color, etc.
Image Recall
30 images recallable, retrieval
Image Archive
Up to 500,000 images stored automatically, enable transferring to USB disk, and converting to JPG, BMP and other general formats
Real-time Curve
Real-time curve to see if the detection system and other components work well
Others
Fault diagnosis, system time setting, detection blind dots delete, x-ray source setting(analoge or digital), alarm setting, images setting, software register, user management, TIP report, data setting(machine working time, x-ray source working time, baggage counter, etc.)
Â
Â
Operating Environment
Â
Operation temperature/Humidity
5ºC-40ºC / 0%-90%(non-condensing)Â
Storage Temperature/Humidity
 -40ºCto 70ºC / 5%-95%(non-condensing)Â
Operation Power
 220VAC(±10%) 50±3Hz (Optional: 100VAC,110VAC,120VAC,200VAC)
Â
Â
Computer and other
Â
Monitor
High Resolution Color, LCD Accord, 17inch
Hard Disk
SEAGATE 500G 3.5"
CPU
Cortex A9
Storage
1GB
Main board
IMX6_mainboard-V030, made by Safeway
Safeway System -
Â
factory price, with best quality
Â
The scorching summer is here. I think all of you are taking measures to reduce the sun and heat. Today I summarized the basic knowledge and installation skills of the loader air conditioning system to share with the majority of loader drivers and friends, so that you can enjoy this summer To a cool driving environment.
1. The composition of the loader air conditioning system
The air conditioning systems used on loaders all use a method called evaporative compression refrigeration system. This system consists of a compressor, condenser, liquid storage and drying bottle, expansion valve and evaporator. These components are connected by aluminum pipes or hoses, and the refrigerant is placed in this sealed piping system (refrigeration cycle).
Second, the principle of air conditioning refrigeration cycle
The air-conditioning compressor is driven to rotate by the engine. The high-temperature and high-pressure refrigerant vapor discharged from the compressor enters the condenser through the high-pressure hose. Because the temperature of the high-temperature and high-pressure refrigerant vapor is higher than the temperature of the air outside the car, the condenser fan is used to make the condenser The heat of the refrigerant vapor is taken away by the air outside the vehicle, condensing the high temperature and high pressure refrigerant vapor into a higher temperature and high pressure liquid, which flows into the drying bottle through the high pressure hose, and flows through the expansion valve after being dried and filtered.
Under the throttling action of the expansion valve, the refrigerant becomes a low-temperature, low-pressure liquid and enters the air-conditioning evaporator. It vaporizes at a constant pressure and absorbs the heat of the air outside the evaporator tube, so that the air flowing through the evaporator is circulated in the Cabin. The lowered temperature becomes cold air, which is sent into the cabin by a blower to lower the air temperature in the cabin. The vaporized refrigerant vapor is sucked and compressed by the compressor, and then becomes high-temperature, high-pressure refrigerant gas, which is pressed into the condenser through a high-pressure hose, completing a refrigeration cycle of the air conditioning system.
Three, operation panel instructions
The control panel on the outer cover is as shown in the figure. The functions of these switches and indicators are:
1. Refrigeration switch: used to control the work of the air-conditioning compressor.
2. Air volume switch; used to control the speed of the evaporator fan in order to select the appropriate air volume.
3. Indicator light: red light on means that the blower is running and the system is working; green light on means that the compressor is started and the refrigeration system is working.
Adjusting the angle of the air outlet can change the angle and direction of the cold air blowing; adjusting the air volume switch can obtain three levels of air volume: high, medium and low.
Fourth, the installation skills of the main components
The installation of the main components is a crucial part of the air conditioning system debugging. The quality of the main components of the air conditioner is completed by the supplier and the OEM. The main components of the air conditioner can only be regarded as semi-finished products from the supplier to the OEM. They must The system can be connected through the OEM to form a complete body. Therefore, the quality of the installation of air conditioners in the production line of the main engine factory directly affects the quality of the air conditioning system.
Unscrew the dust cap when the compressor pipe heads are connected. Do not place the pipe heads below the level to prevent lubricant leakage. When connecting the belt with the driving pulley, check the belt tension straightness, and the allowable error is between 0~1.5 mm. The method of checking the belt tension is as follows: use the middle finger to forcefully press down on the center belt point of the two wheels, the elastic pressure range is between 4~7mm.
During the transportation process of the condenser assembly, be careful to handle it gently, and do not damage the collecting pipe and rectangular pipe to prevent refrigerant leakage. When installing, pay attention to the big pipe head facing up and the small pipe head down. Unscrew the dust cap when the pipe heads are connected. When the pipe head is locked, use two wrenches to tighten it in opposite directions, because the condenser is Aluminum, so pay attention to force to prevent the lock from breaking. Avoid high-temperature areas and sharp-angle areas when wiring lines to prevent burns or wear.
The liquid storage drying bottle should be opened after the preparations are completed to prevent the inhalation of moisture in the air. There is a glass sight glass on the head of the liquid storage drying bottle. Be careful not to scratch it to prevent refrigerant leakage. Pay special attention to the butt joint of the tube head. The direction of the arrow on the end marked with "â†" on the liquid storage drying bottle must be connected to the evaporator.
During the transportation process of the evaporator assembly, be careful to handle with care and do not damage the pipeline to prevent refrigerant leakage. Unscrew the dust cap when the pipe heads are connected. When the pipe head is locked, use two wrenches to tighten it in opposite directions, so that the expansion valve cannot be loosened.
5
The hot summer has come, and the main components of the air-conditioning system have become the main loss materials in the season. A loader without an air-conditioning system cannot be regarded as a complete machine. Drivers and friends will inevitably have to drive the loader in an environment without cooling. All kinds of discomfort, which easily increase the operational risk. To understand the basic knowledge of the loader air conditioning system, master the installation skills of the main components, to ensure that the loader air conditioning system can be stably refrigerated, and to create a cool and comfortable driving environment, which is very important to our loader drivers