Method for measuring chlorophyll content of paste-like objects
Chlorophyll Content Determination Method for Paste Objects Chlorophyll is an important food pigment, which is classified into chlorophyll a and chlorophyll b. Its basic structure is a magnesium-bound porphyrin ring. Chlorophyll meter can be used to measure the chlorophyll content in the leaves of plants, but for the determination of the solution chlorophyll content can not use the chlorophyll meter, and the cream chlorophyll extracted from the leaves of plants is important for the preparation of various chlorophyll derivatives It is of great significance to establish an effective analytical method to determine the content of the intermediate, and the chlorophyll content of the paste cannot be measured using a chlorophyll meter. At this time, it is necessary to select other methods for measurement, and it is possible to use the atomic absorption Spectrometer to perform accurate measurements.
CNI offer nanosecond pulsed diode Laser, with tunable pulse width 10ns-10ms (external trigger), good beam profile and high power stability. It has ultra compact design that can be easily integrated into customers instrument. This series laser can be widely used in microelectronics, solar energy, material processing, equipment integration, etc..
Specifications
Dimensions
121(L) ×50(W) ×30.8 (H) mm3,0.3kg
121(L) ×50(W) ×30.8 (H) mm3,0.3kg
Infrared Nanosecond Laser,Nanosecond Laser,Nanosecond Pulse Laser,Nanosecond-Pulsed Laser Co-Irradiation Changchun New Industries Optoelectronics Technology Co., Ltd. , https://www.lasersciences.com
The paste-like chlorophyll is mainly sodium magnesium chlorophyllin. During the test, 0.100 5 g of sodium chlorophyllin is weighed and formulated into a stock solution of 50.00 mL of chlorophyll. Accurately transfer 1.00 mL sodium chlorophyllin solution to 8 50.00 mL volumetric flasks, and then add 0.00, 2.00, 2.20, 2.40, 2.60, 2.80, 3.00, 3.20 mL of 50.00 mg·L-1Mg2+ standard solution respectively, to constant volume. Shake well. Click to determine the environment requirements using the atomic absorption spectrophotometer to measure and draw the working curve, and calculate the linear regression equation. This linear equation can be used to calculate the chlorophyll content.
Model
Wavelength
Output Power (mW)
User Trigger Frequency (MHz)
Pulse width
MDL-NS-405
405
1-500
1Hz-80MHz
10ns-10ms
MDL-NS-450
450
1-80
1Hz-50MHz
10ns-10ms
MDL-NS-520
520
1-100
1Hz-50MHz
10ns-10ms
MDL-NS-635
635
1-200
1Hz-40MHz
10ns-10ms
MDL-NS-642
642
1-80
1Hz-30MHz
10ns-10ms
NDL-NS-655
655
1-180
1Hz-30MHz
10ns-10ms
MDL-NS-785
785
1-100
1Hz-30MHz
10ns-10ms
MDL-NS-808
808
1-100
1Hz-40MHz
10ns-10ms
MDL-NS-830
830
1-120
1Hz-20MHz
10ns-10ms
MDL-NS-852
852
1-150
1Hz-30MHz
10ns-10ms
MDL-NS-915
915
1-200
1Hz-30MHz
10ns-10ms
MDL-NS-980
980
1-200
1Hz-40MHz
10ns-10ms
MDL-NS-1060
1060
1-200
1Hz-40MHz
10ns-10ms
MDL-NS-XXX
Optional Power Supply